It is applied to exterior of all buildings and used as last coat of exterior insulation systems.
• Cement based plasters,
• Exposed Concrete surfaces (Fenix BT applied surfaces),
• Gas Concrete surfaces (Surfaces that plastered with a cement based plaster)
• Old surfaces. ( Swelling places on surface must be cleansed, repaired and primed until
surface gets homogeneous before last coating application)
• It should be applied single coat with a coral roller without watering if on textured primed surface.
• In plain applications it should be thinned with water at a rate of %10 and be applied to primed surface with pelt roller.
• Cannot be applicable on wet or humidified horizontal surfaces.
• Modified with silicone resin.
• It can bridge capillary cracks on plaster without any need of repair. (2-3 mm)
• It repels water 100% due to its hydrophobic structure. It repels moisture with its water vapor permeability.
• Easy to apply and leaves no roller mark.
• Does not allow the formation of bacteria and mold
• Resists to sunlight (+60°C to -30°C)
• Texture can be made with chosen roller due to its silk matte brightness.
Touching time: 1 hour
Full drying time: 24 hours
Full setting time: 28 days